• Српски
    • Српски (Serbia)
    • English
  • Српски (ћирилица) 
    • Српски (ћирилица)
    • Српски (латиница)
    • Енглески
  • Пријава
Преглед рада 
  •   ПЛАТОН
  • Природно-математички факултет
  • Главна колекција / Main Collection
  • Преглед рада
  •   ПЛАТОН
  • Природно-математички факултет
  • Главна колекција / Main Collection
  • Преглед рада
JavaScript is disabled for your browser. Some features of this site may not work without it.

A single drop histamine sensor based on AuNPs/MnO2 modified screen-printed electrode

Thumbnail
Отварање
Рад у целини (244.3Kb)
Аутори
Knežević, Sara
Ognjanović, Miloš
Nedić, Nemanja
Mariano, José
Milanović, Zorana
Petković, Branka
Antić, Bratislav
Vranješ Djurić, Sanja
Stanković, Dalibor
Метаподаци
Приказ свих података о документу
Апстракт
In order to ensure high food quality, one of the prime importance is the detection and quantification of histamine, well known marine food poison. In this work, we constructed novel electrochemical biosensor for the detection of histamine based on gold nanoparticles decorated on manganese dioxide (Au/MnO2) and used for modification of screen-printed carbon electrode (Au/MnO2@SPCE). The constructed sensor was then used for the estimation of histamine content in a single drop. Materials used in this study were synthesized and characterized using HR-TEM, XRPD and electrochemical methods. The amperometric detection method was optimized and, under selected operating parameters (supporting electrolyte pH 6, working potential of 1 V), the proposed sensor possesses linear working range from 0.3 μM to 5.1 μM, with a detection limit of 0.08 μM. The effect of selected interferences was investigated and it was found that the developed approach offers accurate, precise, selective, fast and reproducible quantification of histamine using only one drop of the sample. In the end, this work stands as a proof-of-concept of the modified electrodes and electrochemical detection as a promising and prospective approach for the applications in real-time monitoring of the food quality.
URI
https://platon.pr.ac.rs/handle/123456789/1202
DOI
https://doi.org/10.1016/j.microc.2020.104778
М категорија
M21
closedAccess
M21
closedAccess
Колекције
  • Главна колекција / Main Collection

DSpace software copyright © 2002-2016  DuraSpace
О ПЛАТОН репозиторијуму | Пошаљите запажања
Theme by 
Atmire NV
 

 

Комплетан репозиторијумИнституцијеПо датуму издавањаАуториНасловиТемеОва институцијаПо датуму издавањаАуториНасловиТеме

Мој налог

ЛогинРегистрација

DSpace software copyright © 2002-2016  DuraSpace
О ПЛАТОН репозиторијуму | Пошаљите запажања
Theme by 
Atmire NV